Listing filters filter_list

All Products

close

Top Service Providers


What service do you need? SHOPPA ENQUERY

apps format_list_bulleted location_on
  • Open

    NAKSH ELECTRICAL WORKS

    A fire alarm system has a number of devices working together to detect and warn people through visual and audio appliances when smoke, fire, carbon monoxide or other emergencies are present. Currency: 7000 INR Min Order: Bulk Price : Ask for price NAKSH ELECTRICAL WORKS
  • Open

    Technosoft Integrated Solutions Private Limited

    Fire Panel Rs 6,500 / NumberGet Latest PriceMinimum Order Quantity: 1 NumberFeatures:4/8 Class B initiating device circuit (IDC).All zones accept smoke detectors and any normally open contact device.Any Zone can be configured as Alarm or supervisory Zone.Class B Notification Appliance Circuits (NAG).Fully complies with UL -864 and NFPA-72.Rugged CRCA sheet with powder coated finish.Operates on 110 - 220v 50 /0 Hz, AC Mains power supply.Standby (battery) backup 24v DC power supply with but in charger16x2 Dot Matrix LCD Display.Error free Pie / Fault status in unambiguous coloured LED indication.System ON indication.Main, Standby status audible and visual indication.Battery Low visual warning with audible tone.Form C relays for fire, fault and supervisory.Re-settable / uninterrupted 24v D.C. Output.RS 485 Communication facility (Optional).Lamp Test facility.Walk Test facility.Zone Isolation facility with loop voltage cut off.Earth fault annunciation facility at 0 ohms.All field wiring circuits are Power limited except 110 - 220v AC and Battery.All field wiring circuits are supervised.AC Low voltage cut-off.Programmable NAC's.Programmable IDC's.Programmable Supervisory Mode.Programmable AC loss delay.Alarm verification facility.Programmable Trouble reminder facility.Specification:Primary Power CN1 (RE-SMPS-4A-R1) : 110 - 220VAC 10%, 50 Hz, 2.5Amps.Standby Power CN10 : 24v D.0 (2 No of 12v, 12Ah Sealed Lead acid battery).Operating Condition :Operating Temperature 0 - 49 C/32-120 F.Relative Humidity 93 2% RH (non -condensing) at 322 C190 3 F.Charging Circuit :Charging Voltage 28.2V, 0.5VCharging Current 800mA (Max).Initiating Device Circuits CN 8 :All zones are Class : B Style B/C operation (Programmable).Normal Operating Voltage : 14 - 21 VDC.Alarm Current : 15 30mA.Short Circuit Current : 45mA Maximum.Loop resistance : 100 ohms Maximum.End-Of-line Resistor : 3K9, 1/2wattStandby Current : 7mA (2mA for Detectors)Notification Appliance Circuits CN5 and CN6 :Class : B Style - Y wiringOperating Nominal Voltage : 24VDC Special ApplicationCurrent for all NACs : 1.2Amps (0.6A per circuit)Current Limit : CN5 and CN6 via Thermal FuseLine Drop : 1.8VEnd-Of-Line Resistor : 3K9, 1/2wattNote: For compatible devices refer Chapter 9(CD 01 ).D.C. Power CN7 : Operating Voltage: Supervised 24VDC regulated, 300mA Max. (for 4 wire smoke detector)Common Three Form C Relays CN2, CN3, CN4 : Relay Contact Rating: 2Amps @ 30 VDC, 2Amps @ 30VAC. Power Factor 0.6Additional Information:Item Code: RE-2554-2558 Currency: INR Min Order: Bulk Price : Ask for price Technosoft Integrated Solutions Private Limited
apps format_list_bulleted layers

#1 Business Directory and Service Provider

Shoppa holds millions of buyers who are willing to purchase the product at a negotiable rate. Enlist your business product and become Shoppa Seller right now.